IMA CNC lathe Siemens ET 200SP PLC fault diagnosis
EUR 1 000.00
EUR 250.00/jour · forfait · fonds sous séquestre
Jours
4
Disponibilités
1er févr. au 12 févr.
Compétences requises
PLC AutomationSiemens TIA PortalElectrical TroubleshootingTroubleshooting & Fault FindingSiemens PLC Diagnostics+5 autres
PlanningPas le dimanche
AvantagesTransport fourniHôtel pris en charge
Périmètre des travaux
An IMA CNC lathe requires on-site electrical and automation troubleshooting to resolve recurring control module faults. A Siemens SIMATIC ET 200SP distributed I/O station frequently enters error state during operation.
- Intermittent fault diagnosis on a Siemens SIMATIC ET 200SP station (IM 155-6 PN/2 HF) with digital input and output modules
- Interrogation of diagnostic buffer and PLC logic via Siemens TIA Portal
- Inspection and testing of 24V DC field wiring, power distribution, and Profinet communication
- Plan for 32 hours of work, with machine availability from 01 February 27 to 12 February 27
Éléments visuels
PLC module frequently goes into error, need troubleshooting.
Exigences et compétences
Technique
PLC Automation
Siemens TIA Portal
Electrical Troubleshooting
Troubleshooting & Fault Finding
Siemens PLC Diagnostics
PLC Troubleshooting
Industrial Networking (Profinet/EtherNet IP)
Voltage & Current Testing
Electrical Schematic Reading
Root Cause Analysis
Marques
IMA
Secteur
Machine Tool Technology
Types de machines
CNC Lathe
Type de travail
Diagnostic de panne
Consignes du site
Hard hatESD protectionLOTO certificationHi Vis vest